SH1 (Laminate)

O

3

12-mil Aluminum/Polyvinylchloride Laminated Foil Shielding
  • Superior EMI Shielding (1MHz - 20 GHz)
  • Many shape configurations
  • Flame retardant
  • Intended for minimal Flex Applications
  • Low cost

Material Specification No. 3601

Raw materials are not sold separately, please contact the sales department for any special requirements.

Details

SH1 Laminate is a lightweight shielding material that consists of Zippertubing's SH1 shielding foil adhesively laminated to our Type 63-10 Polyvinylchloride jacket material. It can be combined with most Zippertubing closure types to create a thin, lightweight cable jacket with outstanding EMI shielding performance. The material is a general purpose shielding product that is ideal for use in protected areas like electronics racks, and should not be used in areas where a great deal of flexing is likely to occur. It can be configured for Round, Flat and Rectangular cable shapes and is supplied with a sewn-in 15 AWG braided Tin/Copper ground wire running the full length of the product. The lamination is flame retardant and can be Certified to UL224, VW-1 flammability upon request when ordered with our PVC R-Track or Z-Track closures.


Specifications

SH1 (Laminate)

Electrical: Resistance 0.091 ohms/mft @ 1.0"
Fluid Resistance Best
REACH Compliant
RoHS RoHS-10
Dielectric Constant 7
Shelf Life 36 Months
Elongation 200% min., 450% max
Material Thickness 0.011"
Minimum Operating Temperature -4 ° F (-20 ° C )
Maximum Operating Temperature 221 ° F (105 ° C )
Tensile Strength 1,800 psi

Available Attributes

Shielding SH1 (Laminate)

Attentuation Chart

Attenuation data was obtained using MIL-DTL-83528H (modified). Testing was performed by accredited, third-party EMI laboratories.

Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing® products, the user shall determine suitability for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing® shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters which are beyond the control of Zippertubing®. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and patents pending. © 2021 The Zippertubing® Company, Chandler, Arizona.