SHX-2 (S/S)

Stainless Steel Wire EMI Shielding Mesh, 2-Ply
  • EMI Shielding (500 KHz to 500 MHz)
  • Extremely Flexible & Lightweight
  • Extremely Corrosion Resistant
  • Non Flammable & Heat Resistant

Material Specification No. 3104-2

Raw materials are not sold separately, please contact the sales department for any special requirements.

Details

SHX-2 (S/S) is a flexible 2 layer knitted wire mesh EMI shielding material that is made of 304 Stainless Steel wire. The knitted mesh design creates a highly flexible shield that unlike many tubular braids will not change attenuation performance when articulated. The knitted wire mesh maintains constant window spacing during cable assembly movement and as a result yields excellent EMI shielding performance from 500 KHz through 500 MHz. The material is conductive, lightweight and ideal for severe environments and highly corrosive applications. The mesh can be added to most Zippertubing jacket materials to create an easy to install Zip-on EMI shielded assembly. SHX-2 (S/S) shields come with a standard 15 AWG drain wire attached to simplify grounding. This material has been used to provide rodent protection, EMI Shielding in seawater and extremely high temperature applications.


Specifications

SHX-2 (S/S)

Chemical Resistance Good
Ratings Stainless Steel, Type 304
Flat Thickness 0.015"
RoHS-6 Compliant
Shelf Life 60 months
Minimum Operating Temperature -422 ° F (-252 ° C )
Maximum Operating Temperature 1600 ° F (871 ° C )
Tensile Strength 90,000-125,000 psi

Available Attributes

Material Color Bright S/S

Attentuation Chart

Attenuation data was obtained using MIL-DTL-83528H (modified). Testing was performed by accredited, third-party EMI laboratories.

Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing® products, the user shall determine suitability for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing® shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters which are beyond the control of Zippertubing®. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and patents pending. © 2021 The Zippertubing® Company, Chandler, Arizona.