Z-Wrap® (RPU) Cable Bundling

A white, PVC-free, wrap-around cable bundling solution utilizing an adhesive closure, making this solution ideal for medical and clean room applications.

Drawing Number(s): ZT16-04-005

Z-Wrap® (RPU) Cable Bundling
RoHS

Select product options

Please fill in at least one field.
Please fill in the field.
Please fill in the field.
Please fill in the field.
Please fill in the field.
Please fill in the field.
Selected Part Number:ZT16-04-005-0.375-W
Get A Quote
Z-Wrap (RPU) Infographic
  • Fire-retardant, polyurethane-coated polyester jacketing
  • Acrylic adhesive is solvent, humidity, and U.V. resistant
  • Wrap-around product requires no tools for installation – just remove liner and seal closed

Z-Wrap® (RPU) is a permanent, wrap-around cable bundling and protection solution that utilizes our RPU-17 jacketing paired with a high-strength adhesive. The RPU-17 jacketing is made of a flexible, white reinforced polyurethane that is resistant to many fluids, chemicals, and oils, as well as being best in resistance to abrasion. The jacketing is also fire retardant, offers decent flexibility, and contains no PVC material. The fiber-reinforced acrylic adhesive generates a strong bond and a secure seal. The adhesive has excellent resistance to solvent, humidity, and U.V. The adhesive also has a paper release liner allowing for a quick and clean application.

The installation of Z-Wrap® (RPU) can be accomplished quickly, saving time and resources without the hassle of disassembly. Z-Wrap® (RPU) requires no tools for installation; just wrap around the wire or cable, remove the paper release liner from the adhesive strip, and seal. Z-Wrap® (RPU) can also be cut to any desired length with a pair of standard scissors.

Z-Wrap® (RPU) is offered in diameters ranging from 0.375” to 8”, with custom sizes available upon request. The operational temperature range is -40°F to 160°F (-40°C to 71°C).

* Z-Wrap® (RPU) is not manufactured using a clean room in sterile conditions, but with the right procedures, it could be used in the medical field, including in hospitals, operating rooms, trauma centers, and emergency rooms.

Overall Performance

  • Diameter: 0.375" (3/8)
  • Closure: Tape (Plasticizer Resistant)
  • Material: RPU-17
  • Maximum Operating Temperature: 159°F
  • Minimum Operating Temperature: -40°F
  • RoHS: RoHS-10
  • Shelf-Life: 24 months

RPU-17

  • Solvent Resistance: Very Good
  • REACH: Compliant
  • Flame Retardant: NFPA-701 (2 Sec.) and FAR-25.853a 12 sec. vertical
  • Thickness: 0.017"
  • Material: Polyether Urethane Impregnated PET
  • Maximum Operating Temperature: 160°F
  • Minimum Operating Temperature: -40°F
  • RoHS: RoHS-10
  • Shelf Life: 60 months
  • Tensile Strength: 170 x 150 lbs/min

Tape (Plasticizer Resistant)

    Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing® products, the user shall determine suitability for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing® shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters which are beyond the control of Zippertubing®. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and patents pending. © The Zippertubing® Company, Chandler, Arizona.
    Zip-On® (63) Military-Grade Cable Bundling  Zip-On® (PFR) Polyurethane Cable Bundling  Z-Coil Self-Closing Cable Jacketing
    NAME ZIP-ON® (63) MILITARY-GRADE CABLE BUNDLING  ZIP-ON® (PFR) POLYURETHANE CABLE BUNDLING  Z-COIL SELF-CLOSING CABLE JACKETING
    DESCRIPTION A wrap-around cable bundling and protection solution that has a PVC, military-grade jacket that is abrasion and fluid resistant, with a pressure track.  A wrap-around cable protection solution that is flexible, resistant to abrasion and fluids, and has a pressure track closure.  A self-closing wire bundling and protection sleeve made from a durable, flame-retardant, woven PET material
    Closure Z-Track (PVC), R-Track (PVC), D-Track (PVC), EZ-Track (PVC)  Z-Track (PFR)  Self-Closing
    RoHS RoHS-10  RoHS-10  RoHS-10
    Abrasion Resistance Best  Best  Better
    Installation Type Wrap-Around  Wrap-Around  Wrap-Around
    Purpose Sleeve  Sleeve  Sleeve
    Min Temperature Low  Moderate  Extreme
    Minimum Operating Temperature -4°F  -67°F  -58°F
    Max Temperature Moderate  Low  Moderate
    Maximum Operating Temperature 221°F  225°F  302°F
    Flexibility Better  Best  Best
    View  View  View
    Zippertubing
    Z-Wrap (RPU) Infographic

    Z-Wrap® (RPU) Cable Bundling

    A white, PVC-free, wrap-around cable bundling solution utilizing an adhesive closure, making this solution ideal for medical and clean room applications.

    Drawing Number(s): ZT16-04-005

    Selected Part Number: ZT16-04-005-0.375-W

  • Fire-retardant, polyurethane-coated polyester jacketing
  • Acrylic adhesive is solvent, humidity, and U.V. resistant
  • Wrap-around product requires no tools for installation – just remove liner and seal closed
  • Z-Wrap (RPU)
    Z-Wrap (RPU) wire harnessing
    Z-Wrap (RPU) flexible conduit
    Z-Wrap (RPU) wire shielding

    Features

  • Jacketing does not contain any PVC material
  • Can be cut to any desired length
  • Operational temperature range is -40°F to 160°F (-40°C to 71°C)
  • Benefits

  • No tools are required for installation
  • RPU-17 jacketing is resistant to fluids and abrasion
  • Perfect cable bundling for clean room applications
  • Z-Wrap® (RPU) Cable Bundling

    Specifications subject to change without notice. All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy or completeness is not guaranteed under all circumstances. Before using Zippertubing® products, the user shall determine suitability for the intended use, and user assumes all responsibility for improper selection. Published attenuation values of Zippertubing® shielding have been verified by laboratory testing of the respective shielding materials. Actual installed attenuation values may differ due to installation techniques and final assembly operation parameters which are beyond the control of Zippertubing®. Actual attenuation values can only be determined by the end user testing the completed assembly. U.S. and International Patents and patents pending. © The Zippertubing® Company, Chandler, Arizona.

    Z-Wrap® (RPU) Cable Bundling

    MATERIAL SPECIFICATIONS

    Product Recommendations